Details
Chemical Formula:
Li7-xLa3Zr2-xTaxO12(x=0.4~0.7)
| Product Code | MA-EN-SS-0145 | |
| Test Items | Test results | Method |
| Appearance | White powder, uniform and free of foreign matter | Visual inspection |
| Structure | Cubic phase, conforms to PDF#80-0457 | X-ray diffractometer |
| Particle Size - D50 (μm) | 2.41 | Particle size analyzer |
| Moisture (ppm) | 76 | Karl Fischer titrator |
| Ionic Conductivity (mS/cm) | 0.72 | Sintered ceramic pellet, tested by electrochemical workstation at 25℃ |
| Test Conditions 1.XRD Test: Sample preparation in a low-humidity environment, tested over a 2θ range of 10–90°. 2.Ionic Conductivity Test: Take an appropriate amount of powder, pour it into a 10mm-diameter pellet die, press at 350MPa to form a pellet, then sinter at 1200℃ for 4h to obtain a ceramic pellet. Grind and polish the pellet with 400–800–2000 grit sandpaper, then sputter gold on both sides. Note: After gold sputtering, the side surfaces must be ground clean. Test EIS with an electrochemical workstation: frequency 7MHz–1Hz, amplitude 10mV. (The sintering schedule is for reference only; the optimal sintering parameters can be adjusted according to the specific sintering process, which has a significant impact on the ionic conductivity of the test sample.) 3.Electronic Conductivity Test: Test i-t on the sintered ceramic pellet: constant voltage 0.5V, test duration 1800s. 4.Particle Size Test: Laser diffraction, disperse the powder with ultrasound for 3min. |
||
XRD spectrum

Electrochemical Impedance Plot