Details
The material needs to be vacuum sealed for storage
The material is highly hygroscopic, so it is essential to control the dew point temperature to be ≤ -30 ℃ throughout the entire production process
The electrolyte used during testing is sodium ion electrolyte KLD-NC06
Baking conditions for electrode: Bake at 105 ℃ for 4 hours
Cathode electrode material for sodium ion batteries, polyanion type, material sensitive to moisture, excellent cycling performance
Physical and chemical properties:
| Test Item | Unit | Specification | Measured Result | Test Method or Instrument | ||
| Chemical Composition | Na | wt% | 14.0 ± 2.0 | 14.88 | ICP | |
| P | wt% | 20.0 ± 1.0 | 19.46 | |||
| Fe | wt% | 25.0 ± 2.0 | 25.02 | |||
| C | wt% | 2.0 ± 1.0 | 2.01 | |||
| Cr | ppm | ≤10.0 | 3.6 | |||
| Cu | ppm | ≤1.0 | 0.2 | |||
| Ni | ppm | ≤3.0 | 1.6 | |||
| Zn | ppm | ≤4.0 | 2.2 | |||
| Physical Properties | Particle Size Distribution | D10 | μm | ≥0.25 | 0.375 | Laser Particle Size Analyzer |
| Particle Size Distribution | D50 | μm | 1.0–4.0 | 1.884 | ||
| Particle Size Distribution | D90 | μm | ≤8.0 | 5.746 | ||
| BET | m²/g | ≥15 | 18.76 | Automatic Specific Surface Area and Porosity Analyzer | ||
| Tap Density (TD) | g/cm³ | ≤2.5 | 1.899 | Tap Density Meter | ||
| pH | / | ≤11.0 | 10.35 | pH Meter | ||
| Moisture Content | ppm | ≤1200 | 794.1 | Moisture Analyzer | ||
| Electrochemical Performance | Initial Discharge Capacity | mAh/g | ≥80.0 | 83.1 | CR2032, 0.1/0.1C (4.0–2.0 V) | |
| Initial Efficiency | % | ≥93.6 | 108.5 | |||
Half-cell testing:

CC-Constant current charging; CV-Constant voltage charging;DC-Constant current discharge
XRD:

Packaging requirements: Vacuum packaging with aluminum-plastic film, outer layer packaged in plastic bags.
Storage requirements: Sealed, stored in a cool and dry place.
Questions Fréquemment Posées
Recherchez ou parcourez les questions courantes pour trouver rapidement des réponses

Besoin de support R&D ?
Parcourez les categories produits cles et reliez les materiaux batterie aux services R&D de Canrd.
Materiaux experimentaux
CategorieCathodes, anodes, electrolytes, separateurs et autres materiaux de recherche batterie.
Acheter des materiaux cathode, anode et electrolyte →Equipement de laboratoire
CategorieEquipements de laboratoire batterie pour lignes pilotes, outillages et workflows de test.
Parcourir les equipements de laboratoire batterie →Electrodes et cellules
CategorieElectrodes personnalisees, cellules seches et composants de cellules pour validation R&D.
Voir les electrodes et cellules batterie personnalisees →Electrolyte sodium
CategorieElectrolytes sodium-ion pour recherche et validation de batteries sodium.
Acheter des electrolytes sodium →Services R&D
ServiceServices R&D batterie complets, de l evaluation materiaux a la fabrication de cellules et analyse de defaillance.
Explorer les services R&D Canrd →Evaluation de materiaux
ServiceCaracterisation, tests electrochimiques et evaluation de compatibilite des materiaux batterie.
Evaluer vos materiaux batterie →Fabrication d electrodes
ServiceFeuilles et rouleaux d electrodes personnalises selon votre chimie cible et vos besoins process.
Demander une fabrication d electrodes →Fabrication de cellules
ServiceCellules seches, cellules assemblees et formats personnalises pour validation R&D.
Construire des cellules de recherche personnalisees →Contact
PageDemandez a Canrd d associer produits, materiaux et services a votre projet.
Obtenir un support produit et R&D →