Details
| Physical and chemical properties | |||||||
| Serial Number | Test items | Units | Specifications | Measured results | Inspection method or instrument | ||
| 1 | Chemical composition | Me | (wt%) | 60.0±2.0 | 60.27 | ICP | |
| 2 | Ni | (wt%) | 50.5±2.0 | 50.52 | |||
| 3 | Co | (wt%) | 6.5±1.0 | 6.49 | |||
| 4 | Mn | (wt%) | 3.2±1.0 | 3.26 | |||
| 5 | Ni | (mol%) | / | 83.0 | |||
| 6 | Co | (mol%) | / | 11.0 | |||
| 7 | Mn | (mol%) | / | 6.0 | |||
| 8 | Fe | (wt%) | ≤0.01 | 0.0008 | |||
| 9 | Cu | (wt%) | ≤0.005 | 0.0006 | |||
| 10 | Na | (wt%) | ≤0.03 | 0.0087 | |||
| 11 | Ca | (wt%) | ≤0.02 | 0.0040 | |||
| 12 | Zn | (wt%) | ≤0.005 | 0.0005 | |||
| 13 |
Free potassium |
(wt%) | ≤0.2 | 0.1296 |
Acid burette |
||
| 14 | Physical Properties | Particle size distribution | D10 | (μm) | ≥4.0 | 6.23 | Laser particle size analyzer |
| 15 | D50 | (μm) | 10.0~14.0 | 11.43 | |||
| 16 | D90 | (μm) | ≤28.0 | 20.03 | |||
| 17 | BET | (m2/g) | 0.2~0.7 | 0.52 | Automatic specific surface and porosity analyzer | ||
| 18 |
TD |
(g/cm3) | ≥2.0 | 2.41 |
Tapped density measuring instrument |
||
| 19 | pH | / | ≤12.5 | 11.81 |
pH meter |
||
| 20 | Electrochemical Performance | First discharge capacity | (mAh/g) | ≥190.0 | 200.3 | CR2032 0.1/0.1C(4.3-2.8V) |
|
| 21 | First Time Efficiency | (%) | ≥90.0 | 91.5 | |||




Packaging requirements: Inner layer sealed plastic bottle, outer layer aluminum-plastic film sealed.
Storage requirements: Sealed, store in a cool, dry place.
Material requires vacuum sealing for storage.
Material is hygroscopic; humidity must be controlled throughout the sheet preparation process.
Electrolyte used for testing: Ternary electrolyte (KLD-LP04).
Electrode baking conditions: Baking at 85℃ for 4 hours.
SEM:

Besoin de support R&D ?
Parcourez les categories produits cles et reliez les materiaux batterie aux services R&D de Canrd.
Materiaux experimentaux
CategorieCathodes, anodes, electrolytes, separateurs et autres materiaux de recherche batterie.
Acheter des materiaux cathode, anode et electrolyte →Equipement de laboratoire
CategorieEquipements de laboratoire batterie pour lignes pilotes, outillages et workflows de test.
Parcourir les equipements de laboratoire batterie →Electrodes et cellules
CategorieElectrodes personnalisees, cellules seches et composants de cellules pour validation R&D.
Voir les electrodes et cellules batterie personnalisees →Electrolyte sodium
CategorieElectrolytes sodium-ion pour recherche et validation de batteries sodium.
Acheter des electrolytes sodium →Services R&D
ServiceServices R&D batterie complets, de l evaluation materiaux a la fabrication de cellules et analyse de defaillance.
Explorer les services R&D Canrd →Evaluation de materiaux
ServiceCaracterisation, tests electrochimiques et evaluation de compatibilite des materiaux batterie.
Evaluer vos materiaux batterie →Fabrication d electrodes
ServiceFeuilles et rouleaux d electrodes personnalises selon votre chimie cible et vos besoins process.
Demander une fabrication d electrodes →Fabrication de cellules
ServiceCellules seches, cellules assemblees et formats personnalises pour validation R&D.
Construire des cellules de recherche personnalisees →Contact
PageDemandez a Canrd d associer produits, materiaux et services a votre projet.
Obtenir un support produit et R&D →