Lithium-Ion Battery Performance: Capacity, C-Rate & Cycle Life
When selecting or validating lithium-ion cells, raw mAh numbers are not enough. Engineers and buyers need to understand capacity, voltage behaviour, internal resistance, C-rate, efficiency, cycle life and self-discharge. For a like-for-like comparison, use the same test protocol and state the reference capacity used to calculate C-rate. This article breaks down these indicators using CANRD’s real LFP/graphite pouch cell validation data.
CANRD LFP Pouch Cell Test Overview
CANRD first screened customer-provided LFP cathode material in coin cells, then built ~1 Ah stacked pouch cells with graphite anodes. Initial capacity grading was performed at 25 °C after formation.
| Metric | CANRD Project Result |
|---|---|
| Design capacity | >1,000 mAh |
| Initial charge capacity | 1,072.2 mAh |
| Initial discharge capacity | 956.7 mAh |
| Initial coulombic efficiency | 89.2% |
| Internal resistance | 7.5 mΩ |
The measured initial discharge capacity of 956.7 mAh was below the design target of more than 1,000 mAh. A separate rate test measured discharge capacity retention: three pouch cells were charged at 0.5C under 25 °C, and each cell’s 0.2C discharge performance served as its own 100% baseline. At 7C, the three tested samples retained 79.85-83.11 percent of their low-rate capacity. A standalone charging rate test used 0.2C discharge as the unified baseline.
Core Battery Performance Indicators
1. Capacity & Discharge Energy
Capacity (mAh/Ah) defines the total charge a cell delivers under defined test conditions.
- Design capacity: engineering target for prototype cells
- Rated capacity: declared value tied to specified test conditions
- Measured discharge capacity: recovered charge during discharge (956.7 mAh in this case)
- Discharge energy (Wh): integrates voltage × current, reflecting usable energy instead of only charge. Two cells with identical Ah can deliver different Wh if voltage profiles differ.
For real devices, always evaluate usable energy above the system cutoff voltage, not just rated capacity.
2. Voltage: OCV, Nominal & Working Voltage
- Nominal voltage: simplified reference value for cell classification.
- Open-circuit voltage (OCV): voltage measured after rest with no external load.
- Working voltage: terminal voltage during charge or discharge, which sags under load due to internal resistance.
In the flat region of the LFP open-circuit voltage curve, a small voltage error can translate into a large error in voltage-based state of charge (SOC) estimation. When comparing plateau duration, define a fixed voltage band and measure how long loaded voltage stays within it. Short high-current pulses can pull voltage below the device threshold even when residual capacity remains.
3. Internal Resistance & C-rate
Internal resistance helps explain voltage sag under load. The CANRD case reports 7.5 mΩ without specifying the measurement method or state of charge. Two common measurement types: AC impedance at fixed frequency and DCIR (DC pulse resistance). When comparing resistance values, confirm test method, SOC, temperature and pulse duration.
C-rate expresses current relative to reference capacity. On a 1 Ah cell, 1C = 1 A and 7C =7 A. A higher discharge C-rate increases current demand. It can increase voltage sag and heat generation and cause the cell to reach its discharge cutoff sooner.
Rate test results from CANRD LFP pouch cells (25 °C):
- 0.2C: 100% baseline
- 1C: 92.88%-93.13%
- 3C: 82.63-83.91%
- 5C: 80.31-82.65%
- 7C: 79.85-83.11%
Charging rate also changes behaviour. Raising charge speed from 0.5C to 3C reduced constant-current charging contribution from ~97.1% down to 89.3%–89.9%. Fast-charge evaluation must include time to target SOC and constant-voltage phase duration.
4. Coulombic Efficiency, Energy Efficiency & Self-Discharge
Coulombic efficiency = discharge capacity ÷ charge capacity in one cycle. CANRD’s first-cycle value: 956.7 / 1072.2 ≈ 89.2%. First-cycle coulombic efficiency measures the fraction of charge recovered on the first discharge and reflects first-cycle irreversible capacity loss.
Round-trip energy efficiency is the ratio of discharge energy to charge energy over a defined cycle. It reflects both the charge recovered and the difference between charge and discharge voltages.
Self-discharge describes charge loss while resting at OCV. Valid self-discharge tests specify starting SOC, storage temperature, storage duration and measurement method. For LFP cells, flat OCV limits SOC estimation by voltage alone.
5. Cycle Life & Temperature Performance
Cycle life counts completed cycles until hitting an end-of-life threshold, usually capacity retention or maximum resistance. The test ran for 500 cycles at 25 °C with 1C charging and 1C discharging. Completing 500 cycles only confirms the test duration in cycles; a formal cycle-life claim needs defined EOL criteria and normalized retention data.
Temperature performance splits into charging, discharging and storage. Low-temperature testing must check usable Wh and loaded voltage once the cell reaches test temperature. Storage evaluation checks retained capacity, recharge recovery and resistance growth.
6. Safety
Safety validation uses dedicated electrical, thermal and mechanical tests separate from electrochemical performance tests. Capacity, rate and cycling results do not represent safety compliance.
What Parameters to Request When Comparing Lithium-Ion Cells
| Application Need | Data to Request |
|---|---|
| Longer runtime | Usable Wh and time above minimum voltage at real load |
| Pulse power | DCIR and loaded minimum voltage at target SOC, temperature and pulse width |
| Fast charging | Time to target SOC, charge protocol, cell temperature |
| Long service life | Capacity retention and resistance growth under real cycling profile |
| Storage stability | Retained & recovered capacity at target SOC and storage temperature |
Custom pouch cell projects start with load profile, voltage window, temperature range and lifetime targets. These define the required test matrix and acceptance criteria.
FAQ
Q: Is a higher mAh rating always better?
A: No. Compare usable Wh and runtime above device cutoff voltage under identical load and temperature. Higher mAh only helps if the cell maintains valid working voltage during discharge.
Q: Can the 7C test result be used as continuous discharge rating?
A: Not directly. Continuous discharge ratings require separate validation for voltage, temperature and duration limits. CANRD’s data shows relative capacity retention for three samples under controlled rate testing.
Q: Does completing 500 cycles prove a 500-cycle life rating?
A: No. A valid cycle-life claim requires a defined end-of-life criterion. Finishing 500 cycles only means the test ran for 500 cycles.
How to Evaluate a Cell for Your Application
The CANRD case shows how discharge capacity varies with C-rate and how first-cycle coulombic efficiency and internal resistance inform prototype evaluation. LFP pouch cell selection depends not on single headline numbers but a full set of lithium-ion battery performance indicators. For custom cell R&D and validation, start with your application’s real operating profile, not datasheet nominal values.
Produits et services associes
Utilisez les produits et services R&D Canrd pour transformer les connaissances batterie en experiences pratiques.
Boitier coin cell
ProduitBoitiers coin cell pour valider les materiaux et concepts electrochimiques de l article.
Utiliser des boitiers coin cell dans votre prochain test →Electrolyte sodium
CategorieElectrolytes pour recherche sodium-ion, tests de compatibilite et validation de cellules.
Acheter electrolyte sodium pour validation →Fabrication de cellules
ServiceSupport pour construire cellules seches, cellules assemblees ou formats sur mesure.
Demander un support de fabrication de cellules →Materiaux experimentaux
CategorieParcourez les materiaux pour experiences de suivi, benchmarking et developpement produit.
Voir les materiaux batterie experimentaux →


