Battery Raw Material Testing: 7 Tests Every Lot Needs
Battery raw material testing should confirm, for every incoming lot, that the material has the right composition, low impurities, low moisture, the right crystal phase and the right particle size and surface area, with no foreign particles. These seven checks catch most problems before a lot reaches mixing and coating.
This guide is for incoming quality, supplier quality and materials engineers who buy cathode material, graphite, lithium salts or precursors. It explains what each test catches, which materials it matters for, and how to turn the results into an accept or reject decision.
The 7 battery raw material tests at a glance
|
# |
Test |
Typical method |
What it catches |
Most relevant for |
|---|---|---|---|---|
|
1 |
Chemical composition |
ICP-OES |
Wrong stoichiometry or purity |
Cathode materials, lithium salts |
|
2 |
Trace impurities |
ICP-MS, GDMS |
Metal contaminants |
All active materials and salts |
|
3 |
Moisture |
Karl Fischer titration |
Water that degrades electrolyte |
Cathode materials, salts, separators |
|
4 |
Phase and structure |
XRD |
Wrong or mixed crystal phases |
Cathode and anode materials |
|
5 |
Particle size |
Laser diffraction |
Off-spec size distribution |
Powders |
|
6 |
Surface area and density |
BET, tap density |
Changes in reactivity and loading |
Powders |
|
7 |
Foreign particles |
Magnetic test, SEM-EDS |
Metallic debris, odd particles |
Powders |
Why a certificate of analysis is not enough
Every lot should arrive with a supplier certificate of analysis (COA), and it is worth reading closely. But a COA reports the supplier's own test on the supplier's own sample, often taken before packing and shipping. It may not cover every property that matters to your cells, and it cannot show changes that happen in transit, such as moisture pickup.
Independent testing closes those gaps. It checks the lot as it arrives at your site, uses methods you control, and gives you data to discuss with the supplier when something drifts. It also builds a history across lots, so you can see a slow trend before it becomes a rejected lot.
You do not need to repeat every COA test on every lot. Use your own results to decide where the COA can be trusted and where it needs checking.
1. Chemical composition
Composition testing confirms the material is what the label says. ICP-OES measures the main elements, so you can check the lithium-to-metal ratio in a cathode material, the metal ratios in a precursor, or the purity of lithium carbonate or hydroxide. A small shift in stoichiometry can change capacity and stability. For a worked example of the properties that matter in one salt, see these battery-grade lithium carbonate specs.
Compare against: the composition range in your purchase spec and the supplier COA.
Warning signs on the line: Composition outside the spec range; an unexpected capacity shift in early cycling.
2. Trace and ultra-trace impurities
Trace impurity testing looks for small amounts of unwanted elements, usually metals such as iron, copper, zinc or sodium. ICP-MS handles very low concentrations in dissolved samples. Glow discharge mass spectrometry (GDMS) analyses solids directly and suits high-purity materials. Metal impurities can dissolve and deposit inside the cell, which can raise self-discharge or contribute to short circuits.
Compare against: the impurity limits in your spec, element by element. Do not rely on a single "total impurities" figure.
Warning signs on the line: Higher self-discharge or more cells failing an open-circuit voltage hold after formation.
3. Moisture content
Moisture testing measures water in the material, usually by Karl Fischer titration. Water is a problem because it reacts with the LiPF6 salt in common electrolytes to form hydrofluoric acid, which attacks electrode materials and the SEI. Moisture also affects slurry behaviour. Cathode materials, lithium salts and separators are most sensitive, and a powder can pick up water in transit or storage, so test on arrival, not only at the supplier.
Compare against: your spec limit, and record how the sample was packed and stored.
Warning signs on the line: Gassing, rising resistance or slurry that thickens faster than normal.
4. Phase and crystal structure
XRD confirms that the material has the right crystal structure and shows unwanted phases, such as unreacted precursor or a secondary phase from poor processing. Two lots with the same composition can still behave differently if their structure differs. Canrud offers third-party material evaluation by XRD and ICP for this kind of check.
Compare against: a reference pattern from an approved lot and the expected phase in the spec.
Warning signs on the line: Lower first-cycle capacity or a voltage curve that looks different from approved lots.
5. Particle size distribution
Particle size testing reports the spread of particle sizes, usually as D10, D50 and D90, the sizes below which 10%, 50% and 90% of the particles fall. Laser diffraction is the standard method, described in ISO 13320. Off-spec size changes slurry viscosity, coating quality, electrode density and rate capability. A shift in D90 can point to oversized particles that damage the separator.
Compare against: the D10, D50 and D90 ranges in your spec, measured with the same dispersion method each time.
Warning signs on the line: Slurry viscosity drift, coating defects, or electrode density that will not reach target.
6. Specific surface area and tap density
BET gas adsorption measures specific surface area, and tap density shows how tightly the powder packs. Higher surface area means more contact with the electrolyte, which affects SEI formation and first-cycle loss. Tap density affects how much active material fits into an electrode. Both can change even when particle size looks normal.
Compare against: the ranges in your spec, alongside the particle size result.
Warning signs on the line: Higher first-cycle loss or electrodes that come out thinner or thicker at the same loading.
7. Foreign particles and morphology
Foreign particle checks look for metallic debris and odd particles that other tests average out. A magnetic separation test collects magnetic particles, such as iron from worn equipment, for analysis. SEM-EDS images the particles and identifies their elements. A single metal particle can pierce a separator and cause an internal short, so this test matters even when bulk impurity levels pass.
Compare against: your spec for magnetic impurities and the particle shape of approved lots.
Warning signs on the line: Random early shorts or high self-discharge in a few cells rather than the whole batch.
How to build a lot acceptance plan
A lot acceptance plan decides which tests run on every lot and what happens to the result:
- Every lot: the fast, high-risk checks for your material, often composition, key impurities, moisture and particle size.
- First lots and new suppliers: the full set of seven tests, so you have a baseline.
- Periodic: the full set again on a set schedule, or after a supplier changes process or site.
- Sampling: take samples the same way each time and keep a retained sample from every lot.
- Borderline results: retest the retained sample before rejecting, and share the data with the supplier.
Taking a sample that represents the lot
A test result is only as good as the sample. Powders can separate in transport, with fine and coarse particles ending up in different parts of a drum or bag. Take sub-samples from several containers and several depths, combine them as your procedure says, and record where each came from. Moisture-sensitive materials should be sampled in a dry environment and sealed straight away, otherwise the moisture result describes your sampling, not the material.
Testing has limits. It checks a sample, not every gram of a lot, so poor sampling can hide a problem. It also shows whether a lot meets spec, not whether the spec is right for your cells. If cells from a passing lot still behave badly, the next step is cell-level testing and, if needed, failure analysis.
Lot-release checklist
- Supplier COA received and checked against the purchase spec.
- Sample taken with the agreed method and a portion retained.
- Composition and trace impurities within spec.
- Moisture within spec, with packaging condition recorded.
- Particle size, surface area and tap density within spec.
- XRD and foreign particle checks done where the plan requires them.
- Result recorded and lot released, held or rejected.
Frequently asked questions
Is a supplier certificate of analysis enough?
A certificate of analysis (COA) is useful, but it is the supplier's own data on their own sample. Run independent checks on first lots, new suppliers and any lot that behaves oddly in production, then periodically after that. Compare your results with the COA; a gap between them is a finding in itself.
Which tests should run on every lot?
A common approach is to run quick, high-risk checks on every lot, such as composition, key impurities, moisture and particle size. Fuller checks like XRD, surface area and SEM then run on first lots, new suppliers or a set schedule. The right split depends on your material, process and spec.
How much sample does a lab need?
It depends on the tests and the material. Moisture-sensitive powders need sealed, dry packaging, and some tests use only a small amount while others need more. Ask the lab for the amount per test before you take the sample, and keep a retained portion from the same container.
What limits should we test against?
Test against your purchase specification, agreed in writing with the supplier. Generic numbers from the internet rarely match your chemistry, cell design or process. If you do not have a written spec yet, use the supplier's datasheet as a starting point and tighten it as you learn which properties affect your cells.
|
Got a new supplier or a lot you are unsure about? Canrud tests battery materials for R&D and production teams. Tell us the material and your spec, then request a testing quote. Testing is quoted after a short scope call, all costs listed upfront. Questions first? Canrud's team can help you choose the tests. |
Produits et services associes
Utilisez les produits et services R&D Canrd pour transformer les connaissances batterie en experiences pratiques.
Boitier coin cell
ProduitBoitiers coin cell pour valider les materiaux et concepts electrochimiques de l article.
Utiliser des boitiers coin cell dans votre prochain test →Electrolyte sodium
CategorieElectrolytes pour recherche sodium-ion, tests de compatibilite et validation de cellules.
Acheter electrolyte sodium pour validation →Fabrication de cellules
ServiceSupport pour construire cellules seches, cellules assemblees ou formats sur mesure.
Demander un support de fabrication de cellules →Materiaux experimentaux
CategorieParcourez les materiaux pour experiences de suivi, benchmarking et developpement produit.
Voir les materiaux batterie experimentaux →


