Cell Design Information:
| Battery Chemistry | MnO₂–Zn battery |
| Model | 126510 |
| Cell Dimensions (mm) | 12 mm (T) × 65 mm (W) × 100 mm (L); cell body: 65 × 65 mm |
| Standard Charge/Discharge Current (A) | 1–2 |
| Charge Cut-off Voltage (V) | 1.9 |
| Discharge Cut-off Voltage (V) | 1.0 |
| Electrolyte Used for the Next-page Test Curve | 2 M ZnSO₄ electrolyte (website product: “Zinc ion electrolyte”) |
| Cycle Life | ≥200 cycles under the standard protocol |
Handling and Test Notes:
- Before testing, compress the cell with aluminum plates to the thickness value indicated on the label. Fill with 10–30 mL electrolyte until fully filled, rest for 24 h, then start testing. Test the cell upright with tabs facing upward.
- Standard protocol: 1 A CC charge to 1.9 V; rest 10 min; 2 A constant-current discharge to 1.0 V; rest 10 min; repeat for 200 cycles. If Coulombic efficiency is <100% during the early stage, replenish electrolyte in time.
- Connect according to the “+” and “–” marks on the cell surface. Reversed polarity may cause rapid heat generation.
- Manual measurements may include tolerances.
- Operating ambient temperature: 5–40 °C; charging ambient temperature: 20–35 °C.
- Do not allow metal tools to contact both terminals at the same time; instantaneous high current may damage the cell.
- The cell is not waterproof. Humid environments may cause leakage current or corrosion.
Test Data:

MnO₂ dry cell, 1.2 Ah, 126510 stacked structure (Product Code: CU-PO-ZE-103111)
Electrolyte Used for Testing: 2 M ZnSO₄ electrolyte
Test Procedure: Before testing, compress the cell between aluminum plates to the specified thickness indicated on the label. Inject 30 mL of electrolyte and allow the cell to stand for 24 hours before testing. Test at 25 °C: charge at 2 A constant current (CC) to 1.9 V; rest for 10 min; discharge at 2 A constant current to 1.0 V; rest for 10 min; repeat for 200 cycles.
Need R&D Support?
Browse key product categories and connect battery materials with Canrd's R&D services for testing, fabrication, and project support.
Experimental Materials
CategoryCathode, anode, electrolyte, separator, and other materials for battery research.
Shop cathode, anode & electrolyte materials →Lab Equipment
CategoryBattery lab equipment for pilot lines, fixtures, and testing workflows.
Browse battery lab equipment →Electrodes & Cells
CategoryCustom electrodes, dry cells, and battery cell components for R&D validation.
View custom battery electrodes & cells →Sodium Electrolyte
CategorySodium-ion electrolyte options for sodium battery research and validation.
Shop sodium battery electrolytes →R&D Services
ServiceFull-chain battery R&D services from material evaluation to cell fabrication and failure analysis.
Explore Canrd R&D services →Material Evaluation
ServiceCharacterization, electrochemical testing, and compatibility evaluation for battery materials.
Evaluate your battery materials →Electrode Fabrication
ServiceCustom electrode sheets and rolls based on your target chemistry and process needs.
Request electrode fabrication →Cell Fabrication
ServiceDry cells, assembled cells, and custom-format cell builds for R&D validation.
Build custom research cells →Contact
PageAsk Canrd to match products, materials, and services for your project.
Get product and R&D support →