Details
Operating temperature and relative humidity range | ≤ 70% RH (no water vapor condensation) |
channel control mode | independent control |
protection | power-down data protection; With offline test function; The safety protection conditions can be set, and the setting parameters include: upper voltage limit, lower voltage limit, upper current limit, lower current limit, upper capacity limit, delay time |
Communication Interface | Network Port |
Storage temperature and relative humidity range | ≤ 80% RH (no water vapor condensation) |
Recording frequency | 10HZ |
cycle | cycle test range: 1~65535 times; Number of single cycle steps: 254; Loop nesting: with nested loop function, maximum support for 3-layer nesting |
Charging mode | 1. Constant current, constant voltage, constant current and constant voltage, constant power charging, 2. Cutoff conditions: voltage, current, relative time, capacity, energy,-△V |
database | MySQL database is used to centrally manage test data |
Leakage Current | 0.005μA |
Storage Temperature Range | -10 ℃ ~ 50 ℃ |
noise | <45dB |
current and current detection sampling | four-wire connection |
discharge mode | 1. constant current discharge, constant power discharge, constant resistance discharge, constant voltage discharge, constant current constant voltage discharge, 2. cut-off conditions: voltage, current, relative time, capacity, energy |
Data Record | Time recording interval: 100ms, voltage recording interval: 10mV, current recording interval: range 1: 2uA; Range 2: 20uA; Range 3: 40uA |
channel characteristics | constant current source and constant voltage source adopt double closed loop structure |
DCIR test | support for DCIR calculation at custom points |
Operating Temperature Range | 0 ℃ ~ 40 ℃ (within 25±10 ℃, guaranteed measurement accuracy: accuracy drift 0.005 of FS /℃) |
Chassis size per unit | W483.6mm * D321.5mm * H48.5mm |
pulse mode | charge: constant current mode, constant power mode; discharge: constant current mode, constant power mode; minimum pulse width: 500ms; Number of pulses: a single pulse step supports 32 different pulses; Continuous switching of charge and discharge: one pulse step can realize continuous switching from charge to discharge; Cut-off conditions: voltage, relative time |
Number of Whole Machine Channels | 8 |
input power | AC 220V 10% / 50Hz |
voltage | constant voltage range control: 25mV ~ 5V; Minimum discharge voltage:-5V; Accuracy: 0.05 of FS; Stability: ± 0.05 of FS |
IP protection level | protection level IP20 |
Fixture type | Upper and lower fixture |
data output mode | EXCEL2003,2010, TXT |
input impedance | ≥ 1GΩ |
time | current response time (10% FS ~ 90% FS) <500 μs; Work step time range ① ≤(365*24) hours/work step; ② Time format supports 00:00:00:00(h, min, s, ms) |
Server Disk Configuration | 500GB |
Current | Output range per channel: 5μA ~ 1mA;1mA ~ 5mA;5mA ~ 10mA; Accuracy: ± 0.05 of FS; Constant voltage cut-off current: 2μA;0.01mA;0.02mA; Stability: 0.05 of FS |
input active power | 25w |
Power | Maximum output power of single channel: 0.01W; Stability: ± 0.1 of FS |
& nbsp; & nbsp; & nbsp; Can be used for the detection of lithium battery materials and super capacitors and other batteries.
1. Continuous switching of charging and discharging: One pulse work step can realize continuous switching from charging to discharging;
2. Support the calculation of DCIR by user-defined points;
3. Cycle test range: 1~65535 times;
4. With nested loop function, the maximum support 3 layers of nesting;
5. Protection grade IP20;
6. constant current source and constant voltage source with double closed loop structure.