Details
| Canrd | 10*10cm | 5 sheets/pack | Coating | ||||
| NO. | Electrode Name | Model | Main Material | Active Material Capacity (mAh/g) | Loading | Areal Density (mg/cm²) | Areal Capacity (mAh/cm²) |
| 1 | NCA Electrode | SY51 | NCA-S (Nickel Cobalt Aluminum Oxide) | 195 | 94.50% | 17.66 | 3.25 |
| 2 | Ni90 Electrode | SY41 | Ni90 Single Crystal NCM | 195 | 94.50% | 9.50 | 1.75 |
| 3 | NCM811 Electrode | SY33 | NCM811 Single Crystal | 188 | 94.50% | 9.20 | 1.63 |
| 4 | NCM811 Electrode | SY34 | — | 188 | 94.50% | 21.50 | 3.82 |
| 5 | NCM622 Electrode | SY25 | NCM622 Single Crystal-B | 168 | 96.70% | 10.00 | 1.62 |
| 6 | NCM622 Electrode | SY24 | — | 168 | 96.70% | 21.60 | 3.51 |
| 7 | NCM523 Electrode | SY15 | NCM523 | 165 | 94.00% | 19.70 | 3.06 |
| 8 | NCM523 Electrode | SY13 | NCM523 | 165 | 94.00% | 10.50 | 1.63 |
| 9 | LCO Electrode | LC02 | High Voltage Lithium Cobalt Oxide-Z-4.45V | 178 | 96.40% | 10.00 | 1.72 |
| 10 | LRM Electrode | FL01 | Lithium-rich Manganese-based-E | 280 | 95.00% | 5.96 | 1.59 |
| 11 | Graphite Electrode | SM02 | Natural Graphite (Standard)-A | 340 | 95.70% | 5.80 | 1.89 |
| 12 | Fast Charging Graphite Electrode | SM04 | Fast Charging Graphite-B | 350 | 96.70% | 5.60 | 1.90 |
| 13 | Silicon Carbon Electrode | SC02 | Silicon Carbon Anode 1800 (Porous Carbon Deposited Silicon) | 420 | 95.00% | 4.80 | 1.92 |
| 14 | NFM Electrode | NT02 | Sodium Nickel Iron Manganese Oxide | 127 | 95.50% | 12.27 | 1.49 |
| 15 | NFM Electrode | NT03 | — | 127 | 95.50% | 8.00 | 0.97 |
| 16 | Hard Carbon Electrode | YT02 | Imported Hard Carbon (5 μm) | 300 | 95.50% | 6.00 | 1.72 |
| 17 | LFP Electrode | LF07 | Lithium Iron Phosphate (High Compaction Density) |
150 | 91.50% | 12.30 | 1.69 |
| 18 | LNMO Electrode | NM01 | High Voltage Lithium Nickel Manganese Oxide-B | 130 | 96.00% | 7.50 | 2.00 |
| 19 | NFPP Electrode | NF01 | Sodium Iron Phosphate Pyrophosphate | 100 | 93.50% | 15.30 | 1.43 |
| 20 | Vanadium Pentoxide Electrode | VO02 | Vanadium Pentoxide | 300 | 80.00% | 5.00 | 1.20 |
| 21 | Manganese Dioxide Electrode | MO01 | Manganese-based or Vanadium-based Material | 100 | 80.00% | 5.00 | / |
| 22 | Zinc Negative Electrode | ZA01 | Pure Zinc Powder / Alloy Zinc Powder | / | 70.0%–96.0% | 5.0–15.0 | / |
MOQ for Custom Small Electrode Sheets: 10*10cm/pcs,5cs/pack,1pack
To place an order or request a quotation, please Contact Us.
Storage conditions (vacuum sealing or using self-sealing bags in a glove box, especially for high-nickel and sodium electrode materials, improper storage may lead to increased internal resistance).
Fold marks: Single-sided electrode sheets may curl after rolling, and flattening and packaging may cause fold marks.
The electrode sheets are made of nickel-cobalt-manganese NCM622-C (single crystal), and the electrolytes used during testing are 622 deduction electrolyte and ternary electrolyte (KLD-1230C).
The electrode sheets need to be rolled (it is recommended to roll according to the lowest parameter range of the corresponding electrode sheet compacting), baked at 105°C for 4 hours after punching, left to stand for 8 hours after injection, and the positive electrode sheet needs to be pressure-sealed at 0.02C during constant current charging testing, with a sealing pressure of 1300 psi.
This product must be tested in accordance with the test methods and electrolytes recommended by
Canrd to achieve the corresponding performance.Since the test method and electrolyte have a great
influence on the performance of the battery, any change in the test method or electrolyte may reduce
the performance of the pole piece; be sure to check this information before purchasing.

622 SY2501 Test data


Necesitas soporte R&D?
Explora categorias clave de productos y conecta materiales de bateria con los servicios R&D de Canrd.
Materiales experimentales
CategoriaCatodos, anodos, electrolitos, separadores y otros materiales para investigacion de baterias.
Comprar materiales de catodo, anodo y electrolito →Equipos de laboratorio
CategoriaEquipos de laboratorio de baterias para lineas piloto, utillajes y flujos de prueba.
Ver equipos de laboratorio de baterias →Electrodos y celdas
CategoriaElectrodos personalizados, celdas secas y componentes de celdas para validacion R&D.
Ver electrodos y celdas de bateria personalizados →Electrolito de sodio
CategoriaOpciones de electrolito de ion sodio para investigacion y validacion de baterias de sodio.
Comprar electrolitos de bateria de sodio →Servicios R&D
ServicioServicios completos de R&D de baterias, desde evaluacion de materiales hasta fabricacion de celdas y analisis de fallos.
Explorar servicios R&D de Canrd →Evaluacion de materiales
ServicioCaracterizacion, pruebas electroquimicas y evaluacion de compatibilidad para materiales de bateria.
Evaluar tus materiales de bateria →Fabricacion de electrodos
ServicioLaminas y rollos de electrodos personalizados segun tu quimica y proceso objetivo.
Solicitar fabricacion de electrodos →Fabricacion de celdas
ServicioCeldas secas, celdas ensambladas y formatos personalizados para validacion R&D.
Construir celdas de investigacion personalizadas →Contacto
PaginaPide a Canrd combinar productos, materiales y servicios para tu proyecto.
Obtener soporte de producto y R&D →