How to Measure Pouch Cell Swelling and Thermal Expansion

Canrd November 21, 2026 163

Pouch lithium-ion cells can change thickness as temperature, state of charge, and aging history change. Each type of thickness shift requires a separate testing approach.

  • For module mechanical clearance: Measure thickness under the assembly’s mechanical constraints
  • For thermal expansion coefficient testing: Hold SOC and mechanical boundary conditions steady while varying temperature
  • For aging-related thickness change: Compare thickness at identical reference conditions before and after cycling or storage

Engineers often conflate these distinct thickness behaviours, leading to misinterpreted test data and unreliable design assessments. CANRD pouch cell test data illustrates why separating these effects is critical. In a formation test, group average thickness varied across four formation SOC groups. In an LFP/graphite prototype project, measured thickness was 3.6 mm against a design target of 3.43 mm. These two datasets serve different purposes; one compares formation test groups, the other compares prototype measurement against design specification.

What Causes Pouch Cell Thickness Variation

Different root causes require different control variables and reporting metrics.

Thickness Change Source Parameters to Control What to Report
Temperature-induced thermal expansion SOC, fixture preload, temperature equilibration time Thickness slope (µm/K), effective through-thickness thermal expansion coefficient (K⁻¹ or ppm/K)
SOC-related expansion during charge/discharge Temperature, fixture gap/preload, cycling protocol Thickness vs SOC curve, peak-to-peak thickness change per cycle
Residual thickness growth after aging Fixed SOC, temperature, rest time, fixture and measurement location before & after aging Total thickness increase (µm or %), cycle count / storage duration

Lithiation and delithiation modify the dimensions of active materials. In graphite-based pouch cells, electrode stack thickness can vary with SOC even at nearly constant temperature. Gas accumulation, electrode stack rearrangement and mechanical relaxation also contribute to thickness change. A raw thickness trace alone cannot confirm root cause; supporting characterization data is required. Temperature affects cell thickness directly and can also influence time-dependent processes during extended exposure. Cell design, stacking, pouch packaging and electrolyte formulation all modify the overall thickness response.

How to Calculate Thickness Change and Thermal Expansion Coefficient

Define h₀ = thickness at reference condition; h₁ = measured thickness after change. Use identical measurement location and consistent units.

Thickness change percentage

Thickness change (%) = 100 × (h₁ − h₀) / h₀

For thermal expansion testing: h₁, h₂ = equilibrated thickness at T₁ and T₂, at a fixed nominal SOC under a defined mechanical boundary condition.

Thickness slope = (h₂ − h₁) / (T₂ − T₁) Effective thermal expansion coefficient = (h₂ − h₁) / [h₁ × (T₂ − T₁)]

Slope unit: µm/K. Divide by initial thickness for normalized coefficient (K⁻¹). Multiply by 1,000,000 to get ppm/K. This value represents the average coefficient over the tested temperature window. Use linear fitting across multiple temperature points within the linear response range. Always record fitting range and heating-cooling hysteresis.

Important note: A pouch cell is a layered composite assembly. The measured effective through-thickness coefficient only applies to this exact cell design, SOC, temperature range and fixture condition. If thickness does not return to the original value after cooling back, check for mechanical relaxation or time-dependent contributions before fitting a thermal expansion coefficient.

CANRD Pouch Cell Case Studies on Thickness & Swelling

Formation Study at Four Target SOCs

In CANRD’s pouch-cell formation study, the approximate group mean thicknesses read from the original chart were 3.84, 3.77, 3.64, and 3.58 mm at target formation SOCs of 40%, 66%, 83%, and 93%, respectively. The approximately 0.26 mm difference compares these formation groups. Tracking thickness during charging would require measurements on the same cell throughout the cycle.

LFP / Graphite Pouch Prototype

The stacked 1 Ah-class LFP/graphite pouch prototype had a design thickness of 3.43 mm and a reported measured thickness of 3.6 mm. The approximately 0.17 mm difference is relevant to dimensional clearance. Calculating swelling requires a measured baseline for the same cell under comparable conditions. To calculate an effective thermal expansion coefficient, paired thickness measurements at different equilibrated temperatures are required.

Lab Measurement Workflow for Pouch Cell Swelling

  1. Set mechanical boundary conditions Constant force setup: Track thickness via displacement sensor, report load and contact area. Fixed fixture gap setup: Record force variation and fixture compliance. These two setups answer different mechanical questions. Free to expand measurement conditions better support module gap design, while fixed-gap assemblies focus on force variation with temperature or cycling.
  2. Define repeatable reference condition Lock measurement position, contact geometry, preload, SOC, cell temperature and rest time. Map thickness across multiple points for uneven pouch surfaces. Single-point measurement may miss local bulging. Always account for fixture thermal drift.
  3. Isolate your target variable
  • Thermal expansion test: Temperature-controlled displacement setup, fixed nominal SOC, fully stabilized temperature reading, fixture baseline drift check
  • Cycling swelling test: Synchronously log thickness, current, voltage and temperature
  • Aging measurement: Return to identical reference conditions at every inspection checkpoint
  1. Validate and trace the observed trend A repeating thickness swing that tracks SOC suggests an SOC-related contribution. Residual thickness growth after aging requires inspection of cycle history, fixture performance and internal cell changes. Pair thickness data with complementary characterization methods to confirm root causes.

Common Test Instruments

A temperature-controlled dilatometer or a calibrated displacement fixture can measure through-thickness change directly. For pouch cells, test reports must specify fixture conditions, contact load and correction for fixture thermal displacement.

  • Optical profilometer: Map pouch surface shape and local bulge
  • Temperature-resolved XRD: Measure lattice spacing change of electrode materials
  • Cross-section SEM: Inspect cracks, delamination and electrode stack damage

FAQ

Q1: Is there a universal standard thermal expansion coefficient for LFP pouch cells?

A: No. Use coefficient measured under your specific cell design, electrode stack, pouch material and fixture boundary condition. LFP only defines cathode chemistry. Anode formula and clamping pressure strongly affect results.

Q2: Does pouch swelling always mean gas generation?

A: Not always. Thickness can change from SOC variation, thermal expansion or stack movement under load. First verify whether thickness returns to baseline at matched reference conditions. If gas is suspected, use dedicated gas analysis for independent confirmation.

Q3: Can I use formation and grading temperature records to calculate thermal expansion coefficient?

A: No. Valid calculation requires paired thickness data at identical SOC and mechanical state after full temperature equilibration. Formation and grading represent different electrochemical states and cannot be used directly.

Q4: What equipment is recommended to test pouch cell thermal expansion coefficient?

A: A temperature-controlled dilatometer or a calibrated displacement fixture can measure through-thickness change directly. XRD and SEM are better suited for material mechanism analysis rather than whole-cell thickness testing.

Summary

Pouch cell swelling and thermal expansion coefficient are critical parameters for battery mechanical design and reliability evaluation. Engineers must separate three different thickness mechanisms: thermal expansion, SOC reversible expansion and residual thickness growth after aging. Use standardized calculation formulas and controlled lab test workflows to acquire reliable data. Select suitable instruments and testing methods aligned with your research objective. CANRD provides pouch cell fixtures, custom electrode fabrication and battery testing support for R&D and pilot lines.