Nickel cobalt manganese lithium Ni90 single crystal
Nickel cobalt manganese lithium Ni90 single crystal
Nickel cobalt manganese lithium Ni90 single crystal

Nickel cobalt manganese lithium Ni90 single crystal

$45.31
Molecularformula:
LiNi0.90Co0.05Mn0.05O2
Model:
MA-EN-CA-0002
Classification:
item_No
Specifications
Price
MA-EN-CA-000201
20g
$45.31

Details

This product is a high-nickel single-crystal NCM (Ni90) cathode material developed for advanced lithium-ion battery research. Its single-crystal structure enhances structural stability and delivers high gram capacity, supporting high-energy-density electrode design. The material is moisture-sensitive and requires vacuum sealing with aluminum-plastic film and storage in a cool, dry environment. Electrochemical testing typically uses NCM-specific electrolyte (KLD-1230C) with electrode baking at 85°C for 4 hours. This Ni90 material is commonly applied in half-cell evaluations and studies targeting improved cycling performance and thermal stability for next-generation cathodes.

Lithium ion battery cathode electrode, Ni, Co, Mn NCM material, high nickel, single crystal structure, high gram capacity.

Physical and chemical properties

Serial Number Test items Units Specifications Measured results Inspection method or instrument
1 Chemical composition Li (wt%) 7.0±2.0 7.36  ICP
2 Ni (mol%) 90.0±0.5 90.36 
3 Co (mol%) 5.0±0.5 4.62 
4 Mn (mol%) 5.0±0.5 5.02 
5 Fe (ppm) ≤6.0 2.1 
6 Na (ppm) ≤60.0 29.6 
7 Ca (ppm) ≤50.0 25.7 
8 MI (ppb) ≤60.0 32.4 
11 Physical Properties Particle size distribution D10 (μm) ≥1.0 1.365  Laser particle size analyzer
12 D50 (μm) 3.0~5.0 3.641 
13 D90 (μm) ≤15.0 6.454 
14 BET (m2/g) ≤2.0 0.95  Automatic specific surface and porosity analyzer
15 TD (g/cm3) ≤6.0 1.36 

Vibrating density measuring instrument

16 pH / ≤12.5 11.85 

pH meter

17 Moisture (ppm) ≤600.0 287.0  Moisture Analyzer
18 Electrochemical Performance First discharge capacity (mAh/g) ≥200.0 215.5  CR2032
0.1/0.1C(4.3-3.0V)
19 First Time Efficiency (%) ≥87.0 87.9 

Half battery test

 

 

CC rate charging, CV constant voltage charging, DC rate discharging

 

Packaging requirements: Sealed with vacuum aluminum-plastic film, outer layer packed in plastic bags.

Storage requirements: Sealed, stored in a cool and dry place.

 

The material needs to be vacuum sealed for storage.

The material is prone to water absorption, and humidity control is required throughout the entire production process.

The electrolyte used during testing is NCM electrolyte (KLD-1230C).

Baking conditions for electrode: Bake at 85 ℃ for 4 hours.