Details
Materials need to be stored in vacuum seal
The electrolyte used during the test is: sodium electrolyte (KLD-NF35)
Baking conditions for pole sheets: 110℃ 10h 10Pa (Crystal water is difficult to bake. If the vacuum level of 10Pa cannot reach 10Pa, the temperature needs to be increased to 170℃ and the baking time is > 5 days)
Sodium ion cathode material, prussiate type
Microscopic morphology: Cubic-like shape
| Serial number | Test items | unit | Specification | Test results | Inspection method or instrument | ||
| 1 | Chemical composition | Na | (wt%) | 17.0±2.0 | 17.72 | ICP | |
| 2 | Fe | (wt%) | 35.0±0.5 | 35.25 | |||
| 3 | Mn | (wt%) | 14.5.0±0.5 | 14.25 | |||
| 4 | Na2CO3 | (wt%) | ≤1.000 | N.D. | Titration method | ||
| 5 | NaOH | (wt%) | ≤1.000 | N.D. | |||
| 6 | Physical characteristics | Particle size distribution | D10 | (μm) | ≥2.0 | 2.425 | Laser particle size analyzer |
| 7 | D50 | (μm) | 4.0~6.0 | 5.012 | |||
| 8 | D90 | (μm) | ≤11.0 | 9.502 | |||
| 9 | AD | (g/cm3) | ≥0.2 | 0.30 | Fully automatic specific surface and porosity analyzer | ||
| 10 | TD | (g/cm3) | ≤1.0 | 0.89 | Tapping density measuring instrument | ||
| 11 | pH | / | ≤9.0 | 8.23 | pH meter | ||
| 12 | Moisture | (wt%) | Crystal water | 1945 | Moisture measuring instrument | ||
| 13 | Electrochemical properties | First discharge capacity | (mAh/g) | ≥140.0 | 143.8 | CR2032 0.1/0.1C(4.0-2.0V) |
|
| 14 | First time efficiency | (%) | ≥95.0 | 98.1 | |||


The electrolyte used in the test is: sodium electrolyte (KLD-NF35)
Need R&D Support?
Browse key product categories and connect battery materials with Canrd's R&D services for testing, fabrication, and project support.
Experimental Materials
CategoryCathode, anode, electrolyte, separator, and other materials for battery research.
Shop cathode, anode & electrolyte materials →Lab Equipment
CategoryBattery lab equipment for pilot lines, fixtures, and testing workflows.
Browse battery lab equipment →Electrodes & Cells
CategoryCustom electrodes, dry cells, and battery cell components for R&D validation.
View custom battery electrodes & cells →Sodium Electrolyte
CategorySodium-ion electrolyte options for sodium battery research and validation.
Shop sodium battery electrolytes →R&D Services
ServiceFull-chain battery R&D services from material evaluation to cell fabrication and failure analysis.
Explore Canrd R&D services →Material Evaluation
ServiceCharacterization, electrochemical testing, and compatibility evaluation for battery materials.
Evaluate your battery materials →Electrode Fabrication
ServiceCustom electrode sheets and rolls based on your target chemistry and process needs.
Request electrode fabrication →Cell Fabrication
ServiceDry cells, assembled cells, and custom-format cell builds for R&D validation.
Build custom research cells →Contact
PageAsk Canrd to match products, materials, and services for your project.
Get product and R&D support →