Cylindrical battery automatic component cabinet (5V3A512CH)
Model:
CAN-FOR31-5V3A512CHC
Applied range:
Themain functions of this equipment are the formation of lithium polymer batteries and the capacity sorting of finished batteries. The equipment is mainly composed of automatic clamping mechanism, clamp and plate body for placing clamp, as well as control circuit board, charging and discharging constant current and constant voltage plate, driving switching power supply, etc. installed inside the cabinet. The equipment itself can be operated independently or through an external computer.
Date issued:
2025-01-06 04:18:04
Equipment Size:
1500*860*1820mm
Details
Equipment Size | 1500*860*1820mm |
Power | 16kW |
Weight | / |
Power Supply | AC380V to 220V/50HZ |
process setting | 32 work steps and 255 cycles |
Voltage Accuracy | (0.1%RD +0.1%FS) |
Battery Voltage Range | Charge 0~10V; Discharge 10V ~ 2V |
sorting method | Various conditions (capacity, time, open circuit voltage, discharge platform, etc.) are sorted |
current accuracy | (0.1%RD +0.1%FS) |
Voltage Measurement Range | 0~10V, Resolution: 1mv |
software function | can record voltage, current, time, capacity and other data, has powerful data processing function, provides a variety of curve modes, can output to generate EXCEL database format files, can be connected to MES system |
charging mode | Constant current (CC), constant voltage (CV), constant current and constant voltage |
discharge cut-off condition | voltage, time, capacity |
sampling inspection cycle | whole cabinet inspection ≤ 8S, single channel inspection ≤ 0.1S |
Battery Compatible Range | Length: 20~70mm, OD: 10~32mm |
protection function | voltage abnormal protection, current abnormal protection, over capacity protection, reverse connection protection, power failure protection, data power failure protection |
program upgrade | remote online sending installation package upgrade |
Constant Voltage Range | 2V ~ 10V |
workflow control mode | whole cabinet control |
discharge mode | constant current (CC) |
current range | charging 3mA ~ 3000mA, discharging-3000mA ~ -3mA, resolution 1mA |
charge cut-off condition | voltage, current, time, capacity |
the main functions of this equipment are lithium polymer batteries and capacity sorting of finished batteries. the equipment is mainly composed of automatic clamping mechanism
1. End prompt and abnormal alarm function; Safety protection function;
2. Battery charging function; Battery discharging function; Battery sorting function; Data collection and link and communication with computer;
3. The voltage accuracy does not need to be calibrated, and the current adopts a single-point data calibration function; it has the functions of voltage, current, temperature, and speed inspection;
4. unified ethernet interface for equipment computer.